Pressure Filters

Application

In the pressure circuits of hydraulic and lubrication systems

Preformance Features

Protection against wear: By means of filter elements that, in full-flow filtration, meet even the highest demands rearding cleanliness classes.

Protection against Malfunction:  Through installation near to the control valves or other expensive components. The specific determind flow rate guarantees a closed by-pass valve even at ν ≤ 200 mm²/s (cold start condition).

 

Type Q nom. I/min (GPM) P max. bar (PSI) Connection
D 042 (High Performance) 44 (11.6) 100 (1450) G½(-8 SAE)
D 062 (High Performance) 90 (23.8) 100 (1450) G¾(-12 SAE)

 

 

Type Q nom. I/min (GPM) P max. bar (PSI) Connection
D 162 (High Performance) 205 (66) 63 (914) G1¼(-20 SAE)
D 232 (High Performance) 300 (79.3) 63 (914) G1½(-24 SAE)
D 332 (High Performance) 350 (92.5) 63 (914) G1½(-24 SAE)

 

TYPE Q nom. I/min (GPM) P max. bar (PSI) Connection
D 072 (High Performance) 48 (12.7) 100 (1450) G½ (-8 SAE)
D 112 (High Performance) 130 (34.3) 100 (1450) G1 (-16 SAE)
D 152 (High Performance) 170 (44.9) 100 (1450) G1 (-16 SAE)

 

 

Low-Pressure In-Line Filters

Type Q nom. I/min (GPM) P max. bar (PSI) Connection
FNL 1000 (High Performance) 555 (146.6) 40 (580) SAE2
FNL 2000 (High Performance) 1450 (383) 40 (580) SAE4